Hardy Fall Protection

Standard Tie Back

The original Hardy Tieback that started it all in 2015.

  • 16″, 24″, 32″
  • Made in USA
Hardy Standard Tie Back

The Hardy Tieback (HTB) started it all in 2015: the first pre-manufactured, code-approved roof-mounted anchor. Before it, roof anchors were architect-specified, bolted and custom-built for every job.

It installs between two framing members with SDS screws, comes in 16″, 24″ and 32″, and is fully galvanized.

  • 5,000 lb capacityGalvanized assembly supports 5,000 pounds with no additional engineering.
  • Pull test includedThird-party post-installation load testing is included in California. Ask about other states.
  • Fast installQuick setup cuts labor hours on the roof.
  • PatentedProtected by U.S. Patent Nos. 10,053,878 and 10,358,835 B2.
Hardy Standard Tie Back installed

Specs

Fastening requirements

Hardy Standard Tie Back

Mfg part #DescriptionFastener type & sizeTotal per tie-backWeight
HTB-1616″ Hardy Standard Tie BackSDS Screw – 1/4″ x 3″2495 lb
HTB-2424″ Hardy Standard Tie BackSDS Screw – 1/4″ x 3″32130 lb
HTB-3232″ Hardy Standard Tie BackSDS Screw – 1/4″ x 3″40150 lb
The Hardy Tie Back Device

Free EBM design assistance

We'll design the system around it.

Hardy offers complimentary fall protection design services for architects, owners and structural engineers: anchor design and application, best-system analysis and a façade access plan.

EBM design services
Exterior building maintenance anchor layout plan

Frequently asked questions

When are roof tie-backs required?

Under California Code of Regulations Title 8 §3291, every building 3 stories or 36 feet or more in height must have roof tie-backs or other permanent devices at roof level to secure suspended scaffold hooks, clamps and safety lines. Exceptions apply to buildings using other approved permanent rooftop maintenance systems, and to buildings up to 4 stories or 48 feet when maintenance can be done with extension tools, ladders, approved ground equipment or aerial devices.

Do buildings under 36 feet need fall protection anchors?

Yes, when workers routinely approach within 6 feet of a fall hazard. Routine means four or more times a year, and a fall hazard is an elevation difference of 30 inches or more. A parapet or guardrail 42 inches or higher counts as passive fall protection; below 42 inches, a routine-maintenance fall protection system must be designed.

How far apart should tie-backs be spaced?

Approximately 12-foot intervals, depending on the availability of roof framing members strong enough to carry the loads (Title 8 §3291(f)(2)). Tie-backs may go in structural parapets of adequate strength, as close to roof level as practicable.

Does the building need an EBM design?

If the windows will be washed, that's scheduled maintenance, and window-washing companies must follow an Operating Procedure Outline Sheet (OPOS), which requires an exterior building maintenance (EBM) design by a Scaffold, Inspection and Testing (SIT) company. The EBM design and OPOS aren't needed for the building permit, but are required before scheduled maintenance. Without scheduled maintenance, tie-backs are still required at about 12 ft on center.