Cal/OSHA Title 8 · IAPMO ER-461

Code-approved roof tie-backs.
Half the framing.

The Hardy Saddle installs on one beam instead of two, holds 5,000 lb and needs no roof penetrations. California has the strictest roof anchor rules in the country. Our anchors are built to pass them, so they'll pass yours.

  • ER-461IAPMO UES code evaluation report
  • 5,000 lbCapacity, no extra engineering
  • 1 beamHalf the framing of conventional tie-backs
  • Pull testIncluded with every California install
  • Made in USALA City Fabricators License

Why builders switch

Every tie-back you install on two members is a tie-back you paid for twice.

Conventional roof anchors span two framing members. That's extra lumber, extra blocking and extra labor at every anchor, and code wants one about every 12 feet. The Hardy Saddle needs one.

  • Fits a single beam, double truss or joist system
  • Fastens with SDS structural screws, no membrane penetrations
  • Galvanized, 5,000 lb, no additional engineering
  • Patented: U.S. Patent No. 11,118,363 B1
Meet the Saddle
Conventional tie-back: the anchor spans two framing members2 members
Conventional Spans two framing members, plus blocking, bolts and plates.
Hardy Saddle: the anchor saddles a single beam and fastens with SDS screws1 member
Hardy Saddle Saddles one beam, double truss or joist. SDS screws, no bolts through the roof.

Flagship product

The Hardy Saddle Tie Back.

The roof anchor that once again changed how wood buildings get their tie-backs. Introduced in 2022, it has saved builders millions in time and material.

Hardy Saddle tie-back installed on a beam in a wood-framed roof
Hardy Saddle fitted over a single wood beam
Framer installing Hardy Saddle anchors on a jobsite
12″ · 18″ · 24″Standard sizes at local suppliers. Custom heights and widths available.
5,000 lbGalvanized assembly. No additional engineering.

Title 8 §3291

3 stories or 36 feet? You need tie-backs.

California requires roof tie-backs on every building 3 stories or 36 feet and taller, spaced about every 12 feet, so window washers and painters on suspended scaffolds have something rated to tie off to.

36 ft3 stories or 36 ft and up: roof tie-backs required.
~12 ftApproximate spacing, set by the framing available.
50%Field proof test ceiling: 2,500 lb on a 5,000 lb anchor (§3296).
42″Parapet height that counts as passive fall protection.

How it goes

Plans to pull test. One call.

Hardy handles the anchors, the design help and the test. For full façade access, we bring in our EBM design and installation partners.

  1. Hardy fall protection anchor layout drawing
    01

    We lay it out

    Send your plans. We provide complimentary fall protection design help for architects, owners and structural engineers.

  2. Hardy Saddle tie-backs fastened to beams on the ground before installation
    02

    Your framer installs it

    Framers fasten the Saddle to the beam on the ground before it goes up. Safer and faster than working on the roof.

  3. Hardy tie-back anchor on a finished white roof
    03

    The roof goes on

    SDS screws, no bolts through the membrane. The post comes through the finished roof.

  4. Post-installation pull test of a roof tie-back anchor
    04

    We pull test it

    Title 8 §3296 requires a field test before service. In California, ours is included through Specialized Testing.

We would never install any framing hardware that didn't have a code approval. Why are tie backs any different? Hardy Tie Backs are the way to go.

Darrell Allen, Allen Construction

Watch

See it go in.

Short videos from our channel: the Saddle installed, side by side with a common bolted tie-back, and a real project.

Hardy Saddle vs. Common Bolted Tieback
Springhill Suites Project
Hardy Fall Protection Presentation

Where to buy

Stocked across California.

Hardy products are available at all White Cap, Builders FirstSource and SouthernCarlson locations throughout California.

White CapBuilders FirstSourceSouthernCarlson

Lunch & Learn

We'll come to you.

Get your team up to speed on Cal/OSHA tie-back requirements and the Saddle, straight from the people who designed it.

Book a Lunch & Learn

Tie-back questions, answered.

When are roof tie-backs required?

Under California Code of Regulations Title 8 §3291, every building 3 stories or 36 feet or more in height must have roof tie-backs or other permanent devices at roof level to secure suspended scaffold hooks, clamps and safety lines. Exceptions apply to buildings using other approved permanent rooftop maintenance systems, and to buildings up to 4 stories or 48 feet when maintenance can be done with extension tools, ladders, approved ground equipment or aerial devices.

Do buildings under 36 feet need fall protection anchors?

Yes, when workers routinely approach within 6 feet of a fall hazard. Routine means four or more times a year, and a fall hazard is an elevation difference of 30 inches or more. A parapet or guardrail 42 inches or higher counts as passive fall protection; below 42 inches, a routine-maintenance fall protection system must be designed.

How far apart should tie-backs be spaced?

Approximately 12-foot intervals, depending on the availability of roof framing members strong enough to carry the loads (Title 8 §3291(f)(2)). Tie-backs may go in structural parapets of adequate strength, as close to roof level as practicable.

Does the building need an EBM design?

If the windows will be washed, that's scheduled maintenance, and window-washing companies must follow an Operating Procedure Outline Sheet (OPOS), which requires an exterior building maintenance (EBM) design by a Scaffold, Inspection and Testing (SIT) company. The EBM design and OPOS aren't needed for the building permit, but are required before scheduled maintenance. Without scheduled maintenance, tie-backs are still required at about 12 ft on center.

Who installs the anchors?

Usually the framer. Unless the project spec says otherwise (very rare), the contractor can install fall protection anchors. Hardy recommends the framer install the Saddle on the ground before the beams or trusses go up. It's safer and faster.

Is load testing required?

Yes. Title 8 §3296 requires completed installations to be inspected and tested in the field before initial service. Roof tie-backs are tested to no more than 50% of rated capacity: a 5,000 lb tie-back is tested to no more than 2,500 lb. Hardy includes load testing by the independent agency Specialized Testing.